المبيعات والدعم الفنى : Request A Quote
منزل المنتجاتاختبار زيت العزل أو المحولات

Insulating Oil Power Factor And Loss Tangent Meter In Accordance With IEC61620

Insulating Oil Power Factor And Loss Tangent Meter In Accordance With IEC61620

    • Insulating Oil Power Factor And Loss Tangent Meter In Accordance With IEC61620
    • Insulating Oil Power Factor And Loss Tangent Meter In Accordance With IEC61620
    • Insulating Oil Power Factor And Loss Tangent Meter In Accordance With IEC61620
  • Insulating Oil Power Factor And Loss Tangent Meter In Accordance With IEC61620

    تفاصيل المنتج:

    مكان المنشأ: الصين
    اسم العلامة التجارية: AI
    إصدار الشهادات: ISO
    رقم الموديل: DFT

    شروط الدفع والشحن:

    الحد الأدنى لكمية: 1 مجموعة
    الأسعار: قابل للتفاوض
    تفاصيل التغليف: كرتون
    وقت التسليم: 15 يومًا
    شروط الدفع: Western Union ، T/T ، L/C
    القدرة على العرض: 10000 مجموعة في الشهر
    ﺎﺘﺼﻟ ﺍﻶﻧ
    مفصلة وصف المنتج
    AC HV output: 400V-2200V DC HV Output: 200V-600V
    مقاس: 450 (طول) × 310 (عرض) × 360 (ارتفاع) وزن: 21 كجم
    عرض: رقمي مزود الطاقة: تيار متردد 220 فولت ± 10٪
    Keyword: Loss Tangent Meter,Power factor meter ضمان: 1 سنة

    Insulating Oil Power Factor And Loss Tangent Meter

     

     

    I. Introduction:

    Automatic Insulating Oil Power Factor And Loss Tangent Meter is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc.

    This dielectric loss tangent meter is integrated with oil cup for dielectric loss, temperature-control equipment,temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor,high resistance meter and DC high-voltage power etc.
    The most advanced heating mode of high frequency induction is applied to the heating part of this Insulating Oil Power Factor tester, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. AC-DC-AC conversion mode is applied to AC trial electrical source so that the problem how to measure correctly under the fluctuation of voltage and frequency can be avoided. Even when the electric generator is working, the transformer oil volumn resistivity tester can operate correctly.
    The inner standard capacitor is SF6 three-pole inflate capacitor, whose dielectric loss and capacitance is not influenced by environmental temperature and dampness etc. In this way, the accuracy of insulation oil dielectric loss tangent meter is guaranteed conformably after a long-time application.

     

     

    II. Specifications:

    Condition of Use -5℃-40℃ RH<80%
    Power Source AC 220V±10% Without Frequency Limit
    AC High Voltage Output 400V-2200V ±2% Every 100V 50VA
    DC High Voltage Output 200V-600V ±2%
    Temperature Control Induction Stove Maximal Power 500W
    Temperature Control Range <100℃
    Temperature Measuring Error ±0.5℃
    Control Temperature Error 0.1℃
    Control Temperature Time Room Temperature 90℃ <20min

    Measuring Range

    tgδ Without Limit

    Cx 15PF-300PF

    Rx 10M-10T

    Resolution

    tgδ 0.001%

    Cx 0.01pF

    Rx 0.01

    Precision

    delta tgδ:±(Reading*0.5%+0.020%)

    delta Cx :±(Reading*0.5%+0.5PF)

    delta Rx :±Reading * 10%

    Relative Dielectric Loss Constant Εr Calculated Automatically
    Volume Resistivity ρ Calculated Automatically
    Dimension 450(L)×310(W)×360(H)
    Net Weight 21KG

     

     