Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603

Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603

    • Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603
    • Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603
    • Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603
  • Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603

    تفاصيل المنتج:

    مكان المنشأ: الصين
    اسم العلامة التجارية: AI
    إصدار الشهادات: ISO
    Model Number: GC8890A

    شروط الدفع والشحن:

    الحد الأدنى لكمية: 1 مجموعة
    الأسعار: قابل للتفاوض
    تفاصيل التغليف: لوح صلب
    وقت التسليم: 20 يومًا
    شروط الدفع: L/C ، T/T ، Western Union
    القدرة على العرض: 20 مجموعات شهريا
    ﺎﺘﺼﻟ ﺍﻶﻧ
    مفصلة وصف المنتج
    Test standards: ASTM UOP603 Application: Measure Trace CO and CO2 In Hydrogen and Light Gaseous
    Test method: Gas Chromatagraph ضمان: 1 سنة
    مزود الطاقة: AC220V ± 10 ٪ 50Hz Keyword: UOP603 Gas Chromatagraph

     

    Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603

     

     

    Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603Trace CO and CO2 In Hydrogen and Light Gaseous GC Gas Chromatagraph UOP603

    Spectrogram of UOP603 

     
    1.Principle
    Trace CO and CO2 in the gas sample is injected into the packed column of GC,and methane is generated by the converter. The FID is used to detect the methane product, and the CO and CO2 contents are quantified by the external standard method.
     
    2.Analysis instruments
    2.1 Column A:9.1m1/16 inch OD,0.050 inch ID stainless steel pipe filled 80-100 mesh “TDX-01
    2.2 Column B: 3m1/16 inch OD,0.050 inch ID stainless steel pipe filled 60-80 mesh 13X Molecular sieve;
    2.3 Gas Chromatagraph: constant temperature,FID detector;
    2.4 Gas converter
     
    3 Operation steps
    Repeat to inject standard gas sample to obtain the peak area, and calculate the correction factor of each component with the standard gas content;Re-inject the sample and calculate the sample content from the peak area of each component of the sample.
    R=A/B
    In the formula: A---Content of each component;
    R---Correction factor of each component;
    B---Average peak area of each component,
     
    4 Calculation
    Use below formula to calculate content of each component:
    Content of each component: mass-ppm=E·R
    In the formula: E=peak area of each component;
    R=Correction factor of each component;
     
     