المبيعات والدعم الفنى : Request A Quote
منزل المنتجاتأدوات المختبر

Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector

Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector

    • Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector
    • Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector
    • Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector
    • Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector
    • Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector
  • Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector

    تفاصيل المنتج:

    مكان المنشأ: الصين
    اسم العلامة التجارية: AI
    إصدار الشهادات: ISO
    رقم الموديل: 3100

    شروط الدفع والشحن:

    الحد الأدنى لكمية: 1 مجموعة
    الأسعار: قابل للتفاوض
    تفاصيل التغليف: لوح صلب
    وقت التسليم: 20 يومًا
    شروط الدفع: L/C ، T/T ، Western Union
    القدرة على العرض: 20 مجموعات شهريا
    ﺎﺘﺼﻟ ﺍﻶﻧ
    مفصلة وصف المنتج
    Wavelength range: 190~700nm النطاق الترددي: 8 نانومتر
    طول المسار: 10mm مصدر الضوء: مصباح ديوتيريوم
    كيوارد: HPLC ضمان: 1 سنة

     

    Eclassical 3100 Binary HPLC System 

    Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector

     

     

    P3100 High Pressure Constant Flow Pump
    ◆ Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
    ◆ Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
    ◆ Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
    ◆ Maximum pressure: 45MPa

     

     

    UV3100 UV/VIS Detector

    Wavelength range 190-700 nm
    Wavelength repeatability ≤0.1 nm
    Wavelength accuracy ≤±1.0 nm
    Bandwidth 8nm
    Response time 0.0 s-5 s
    Baseline noise ≤±0.5×10-5 AU
    Drift ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
    Path length 10 mm(analytical cell)
    Light sourcw Deuterium Lamp

     

     

    Chromsoft Chromatographic Data-processing Workstation

    ◆ Internal and external standard calculation methods
    ◆ Automatically displays, prints, exports and starts other programs after the completion of a measurement.
    ◆ Comply with the requirements of the 21 CFR Part 11 directive of the FDA

     

     

    Eclassical 3100 System Kits

    ◆ Containing required tubing, fittings, wreches and cables for system.
    ◆ C18 column 5μm ID4.6×200mm
    ◆ 7725i manual injector
    ◆ TD-1-15 mixer
    ◆ User manual

     

     

    RI-201H Refractive Index Detector

    ◆ Flow cell type:2 chamber-type
    ◆ Measuring method:Deflection type
    ◆ Refractive Index range:1.00 to 1.75
    ◆ Measuring range:0.25 to 512μRIU
    ◆ Drift:0.2μRIU/h (Pure water 1mL/min, PURGE OFF)
    ◆ Linearity range:≥600μRIU
    ◆ Noise:≤2.5nRIU (Pure water, response : 1.5sec)
    ◆ Response:0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
    ◆Cell volume:8μL
    ◆Flow rate:(Usual) 0.2 to 3.0mL/min;(Max.) 10mL/min (solvent: pure water)

     

     