المبيعات والدعم الفنى : Request A Quote
منزل المنتجاتمعدات اختبار الكابلات

Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
  • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

    تفاصيل المنتج:

    مكان المنشأ: الصين
    اسم العلامة التجارية: AI
    إصدار الشهادات: ISO
    Model Number: TUL1666

    شروط الدفع والشحن:

    الحد الأدنى لكمية: 1 مجموعة
    الأسعار: قابل للتفاوض
    تفاصيل التغليف: حالة الخشب الرقائقي
    وقت التسليم: 90 يوما
    شروط الدفع: Western Union ، T/T ، L/C
    القدرة على العرض: 10 مجموعات/شهر
    ﺎﺘﺼﻟ ﺍﻶﻧ
    مفصلة وصف المنتج
    Test standard: UL 1666 Function: determining values of flame propagation height
    كائن اختبار: كابل الناهض Pressure of test chamber: 0-12pa
    الطابق الأول: 1.22 متر الطابق الثاني: 3.66 م
    الطابق العلوي: 2.24 م External dimmension: 7.12mx1.3m wide x2.5m long
    لون: رمادي Measure hole: 305mm by 610mm

    Introduction

    This is a fire test for determining values of flame propagation height for electrical and optical-fiber cables that are for installation vertically in shafts or in vertical runs that penetrate one or more floors.
    The purpose of this test is to determine whether the flame propagation characteristics of these "riser" cables are in accordance with the National Electrical Code.

    Feature

    1. U-shaped pressure gauge: the pressure of the test chamber are maintained at 0-12pa.
    2. Hygrometer: measure the temperature and humidity of the test chamber.
    3. Structure of the test box: the overall structure is made of concrete wall, the first floor is 1.22m, and the second floor is 3.66M. The top floor is 2.24m, and the external dimension is 7.12mx1.3m wide x2.5m long.
    4. The wall structure is a concrete with a density of 1061b/ft3 (1698kd/m), and its thermal conductivity (k) is 0.38btu (0.055w/mk) at 21.1c. The first and second layers are composed of 203mm thick reinforced ordinary weight cement, and the top is composed of a wall structure that can ensure tightness. The measuring holes on the second layer must be vertically above the measuring holes (305mm by 610mm) on the first layer. Each hole is 203mm from the back of the box and 102m from the side of the box
    5. The ignition device is composed of a 1/2 inch steel pipe, a 1/2 inch elbow and a steel ignition dispersion plate.
    6. Install a propane flowmeter at the place of gas injection.
    7. Install exhaust fan and anemometer at the outlet of fan test box.

     

    Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

    تفاصيل الاتصال
    Advanced Instruments Co.,Ltd

    اتصل شخص: Mrs. Sandy

    إرسال استفسارك مباشرة لنا (0 / 3000)

    منتجات أخرى