المبيعات والدعم الفنى : Request A Quote
منزل المنتجاتمعدات اختبار المنتجات البترولية

Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
  • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

    تفاصيل المنتج:

    مكان المنشأ: الصين
    اسم العلامة التجارية: AI
    إصدار الشهادات: ISO
    Model Number: RECC-I

    شروط الدفع والشحن:

    الحد الأدنى لكمية: 1 مجموعة
    الأسعار: قابل للتفاوض
    تفاصيل التغليف: حالة الخشب الرقائقي
    وقت التسليم: 15 يومًا
    شروط الدفع: L/C ، T/T ، Western Union
    القدرة على العرض: 200 مجموعة في الشهر
    ﺎﺘﺼﻟ ﺍﻶﻧ
    مفصلة وصف المنتج
    Standards: ISO1523 And ISO3679 Test method: Rapid Equilibrium Closed Cup
    Flash Point Mearing Range: -30℃~50℃ عرض: شاشات الكريستال السائل
    مزود الطاقة: AC220V ، 50 هرتز أقصى استهلاك للطاقة: 300W
    ضمان: 1 سنة عملية: تلقائي

    Rapid Equilibrium Closed Cup Flash Point Test Instrument

    Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

     

    Introduction

    This Closed cup flash point test instrument is designed and made as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway,aviation, electricity, commercial inspection and science research institution.
    This instrument is specially suitable to determine different kinds of colored paints,oil paints, adhesives,solvents and petroleum products which the closed cup flash point is -30℃~50℃.The instrument is also correspond with ISO1523 and ISO3679.

     

    Characteristics

    1.Designed as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can realize purpose of testing closed cup flash point rapidly and at low temperature.
    2.This low temperature flash point test instrument adopts semiconductor refrigeration device and external water cooling device.The size is small and cooling rate is rapid.Easy to operate.
    3.Test sample needed is less.2ml for each time(4ml for solid sample and semi-solid sample)
    4.The determination procedure is automatically completed except ignition.Test results can be printed automatically.

     

    Technical specifications

    1.Power supply: AC(220±10%)V, 50Hz
    2.Flash point measuring range: -30℃~50℃
    3. Precision of determination:
    Absolute difference between two determinations is lower than 2℃(same operator)
    Absolute difference between two determinations is lower than 3℃(different operators)
    4. Temperature control precision: ±0.5℃
    5. Igniting device:Electric igniting gun
    6. Cooling mode:Semiconductor(with cold water cycle at external connection)
    7. Maximum power consumption:300W
    8. Ambient temperature:5℃~30℃
    9. Relative humidity:30%~80%
    10. Dimension:370mm×280mm×280mm

     

    Accessories List

    No. Name Unit Qty
    1 RECC-I Low Temperature Closed Cup Flash Point Test Instrumnet Set 1
    2 Fuse Φ5×20 10A Piece 2
    3 Power wire(250V 10A) Piece 1
    4 Printing paper Roll 1
    5 Flexible pipe(inner diameter Φ8) Meter 3
    6 5ml Sample injector Piece 1
     

     

    تفاصيل الاتصال
    Advanced Instruments Co.,Ltd

    اتصل شخص: Mrs. Sandy

    إرسال استفسارك مباشرة لنا (0 / 3000)

    منتجات أخرى